Hydrostatic transmissions - making sense of case drain flow - Part 1

Read This First

One of our readers recently wrote to me regarding the following problem:

"I tried one afternoon and evening to determine what was wrong with a hydrostatic transmission by monitoring case drain flow and was confused by the readings I was seeing. There was a flow meter in the transmission pump outlet and another in its case drain that always showed charge pump flow, even though the motor was bypassing profusely. The motor case drain went through the transmission pump case to tank."

What is a hydrostatic transmission?
A hydrostatic transmission consists of a variable-displacement pump and a fixed or variable displacement motor, operating together in a closed circuit. In a closed circuit, fluid from the motor outlet flows directly to the pump inlet, without returning to the tank.

As well as being variable, the output of the transmission pump can be reversed, so that both the direction and speed of motor rotation are controlled from within the pump. This eliminates the need for directional and flow (speed) control valves in the circuit.

Because the pump and motor leak internally, which allows fluid to escape from the loop and drain back to the tank, a fixed-displacement pump called a charge pump is used to ensure that the loop remains full of fluid during normal operation. The charge pump is normally installed on the back of the transmission pump and has an output of at least 20% of the transmission pump's output.

In practice, the charge pump not only keeps the loop full of fluid, it pressurizes the loop to between 110 and 360 PSI, depending on the transmission manufacturer. A simple charge pressure circuit comprises the charge pump, a relief valve and two check valves, through which the charge pump can replenish the transmission loop. Once the loop is charged to the pressure setting of the relief valve, the flow from the charge pump passes over the relief valve, through the case of the pump or motor or both, and back to tank.

Read This Next

What is the significance of case drain flow?

When a pump or motor is worn or damaged, internal leakage increases and therefore the flow available to do useful work decreases. This means that the condition of a pump or motor can be determined by measuring the flow from its case drain line (internal leakage) and expressing it as a percentage of its theoretical or design flow.

How does this apply to hydrostatic transmissions?

When applying this technique to a hydrostatic transmission, charge pump flow must be considered. In most transmissions, the charge pump relief valve vents into the case of either the pump or the motor.

This means that in the circuit described by our reader, where the motor case drain flushed through the transmission pump case to tank, you would expect to see the flow meter in the transmission pump case drain line reading design charge pump flow. Here's why:

Say charge pump flow was 10 GPM, of which 4 GPM was leaking out of the loop through the motor's internals (case drain) and 2 GPM was leaking out of the loop through the pump's internals. The balance of 4 GPM must therefore be going over the charge relief - but still ends up in either the pump or motor case, depending on the location of the relief valve. In this particular circuit, because the motor case drain flushed through the transmission pump case to tank, you would expect to see the flow meter in the transmission pump case drain line reading the sum of these three flows (10 GPM).

Before any meaningful conclusions can be drawn, the case in which the charge pump relief is venting (motor or pump) must be determined and the two case drain lines (motor and pump) must be isolated from each other. If the charge relief vents into the case of the pump, then it is possible to determine the condition of the motor by measuring its case drain flow, but not the pump. If the charge relief vents into the case of the motor, then it is possible to determine the condition of the pump by measuring its case drain flow, but not the motor.

It is not possible to determine the condition of the component that has the charge relief valve venting into it because there is no way of telling what proportion of the total case drain flow is due to internal leakage - unless of course the charge relief can be vented externally while the test is conducted. While it is possible to do this on most transmissions, it's not usually a simple exercise.

Using case drain flows to determine the condition of the components of a hydrostatic transmission, without a thorough understanding of closed circuits, can result in incorrect conclusions and the costly change-out of serviceable components.

For a list of our Eaton pumps and prices, go to our Eaton hydrostatic parts page

Or visit us at our EBay store: Hydrostatic Transmission Service, LLC

HYDRAULIC REPAIR – HYDROSTATIC PUMPS – HYDROSTATIC EQUIPMENT

CALL US FOR YOUR REPAIR ON DIFFICULT TO LOCATE HYDROSTATIC TRANSMISSION REPAIR.

MITSUBISHI, KAWASAKI, DAEWOO, DYNAPOWER, LINDE, REXROTH, UCHIDA, YAMAHA, HITACHI, KOMATSU, LIEBHERR, POCLAIN, VOLVO, VICKERS, CESSNA, HYDROMATIK AND SUNDSTRAND AND EATON CLOSED LOOP AND OPEN LOOP HYDROSTATIC DRIVE PUMPS AND MOTORS.

404 Air Park Rd
Tupelo, MS 38801
Phone: (662) 680-8899
Toll Free: (800) 361-0068

Email: info@hydrostatic-transmission.com

PayPal service to make fast, easy, and secure payments for your Internet purchases!

PayPal for Easy PaymentsBank Transfer Options

We accept major Credit Cards

Disclaimer: All references to OEM words are strictly for reference only and does not imply that we are an OEM distributor.

[Home] [Sundstrand Pump Repair] [Eaton Pump Repair] [Hydrostatic] [Parts Exchange] [Hydrostatic Parts] [Hydrostatic Pumps] [Hydrostatic Repair] [Excavator Pumps] [Equipment Pumps] [John Deere Pump Repair] [Oil Gear Pumps] [Rexroth Pumps] [Sundstrand Repair] [Vickers Pumps] [Buying Pumps] [Denison Pumps] [Hydrostatic Articles] [Railroad] [Snow Equipment] [Agricultural] [Hydraulic Repair] [Lawn Tractor] [Aquaculture Hydrostatic] [Hydrostatic Tractor Repair] [Material Handling] [Hydrostatic Spraying] [Harvesting Equipment] [Chippers,Grinders,Spreaders] [Hydrostatic Spraying Equipment] [Sawmill Hydrostatic] [Industrial Hydrostatic] [Agricultural Hydrostatic Pump] [Hydraulic Repair Parts] [Hydraulic, hydrostatic, robotic, pnuematic, electrical servo, valve, smc, cylinder repair and parts sales wordlwide] [John Deere Lawn Tractor/Lawn Mower/Garden] [Hydrostatic Transmission Service, LLC offers Sundstrand ,Eaton Dynapower] [Hydrostatic Transmission Service, LLC is your one stop pump repair store.] [90 series Sundstrand Hydrostatic] [John Deere Hydraulic Hydrostatic Pumps, Motors, Transmissions Drives] [Sundstrand Hydrostatic Parts and Sundstrand Repair] [Series 40 - Sundstrand Sauer Hydrostatic Transmission] [Series 40 Sundstrand Hydrostatic Parts] [Denison Hydrostatic Parts and Repair] [Denison Problem Solving] [Denison Hydrostatic Repair] [Sundstrand Hydrostatic Parts and Repair] [Sundstrand Hydrostatic Parts and Repair] [Vickers Hydrostatic Repair] [Caterpillar Pumps & Parts] [Warranty] [Links] [Contact Us]